General Guidelines Ensure that treatment is approved by vet and not contraindicated, and that eye protection is worn. Use transparent barrier to protect against cross infection. Clean probe tips before and after use. Application Guidelines First treat local lymph nodes to support healing with the Multi-wavelength cluster at the settings below. Probe Time per Point Dose per Point Pulse Range 60 (or 20) Diode MW Cluster 1 minute 6 J/cm2 20 Hz Then: 660nm: Treat directly over the open lesion at points 1cm apart across the affected area (unless infected) at settings below. Follow up with the Multi-Wavelength Cluster at settings below to cover area. If wound is infected, use higher pulse range and treat wound margin only initially, aiming to resist complete granulation until infection is cleared. Probe Time per Point Dose per Point Pulse Range 660nm 50mW 15 seconds 6 J/cm2 2.5 - 20 Hz (or 1 - 10 kHz if infected) 60 (or 20) Diode MW Cluster 1 minute 6 J/cm2 2.5 - 20 Hz (or 1 - 10 kHz if infected) Frequency of Treatment At least once per week but not more than once a day.